Cool Karel! That's very similar to what we're trying to do here...but
we've been getting stuck on the EDK+ModularDesign. I'm hoping we can
learn from your example which we've promptly downloaded ;-)
Quick question: why did you choose a MB instead of the PPC?
Ron
> Hi all,
>
> I succeded in making a design which partially reconfigures the fpga of the
> ml310 board via the ICAP. The files are read from the sysace with a
> microblaze and written to the ICAP with the opb_hwicap. To be able to use the
> sysace I had to put a macro over the module that is beeing reconfigurated
> which connects the microblaze with the ICAP. At first sight it works very
> well (just finished it today so not a lot of testing has been done). The only
>
> bug that I found until now is that when uploading the partial bitstream of
> the module that is in the full bitstream does not work. You can find my
> design files at:
>
> http://www.elis.ugent.be/~kbruneel/ICAP_MB_3.zip
>
> It still is very messy, but it works. Look in the demo subdir to find some
> bitstreams.
>
> Any feedback will be much appreciated. Certainly improvements to the design.
>
> Regards,
> Karel Bruneel