Re: [partial-reconfig] About PAR errors of EAPR



Hi Enno,

Thanks for your letter!

But the signals that's between PRM and IO do not cross through the
static part. Thus, is BM necessary?

Best regards,
JinXi


2007/10/10, Enno Luebbers <enno.luebbers@xxxxxxxxxxxxxxxx>:
> Hi Jin Xi,
> > ERROR: Net a2_IBUF crosses a region boundary and is not part of a
> > slice macro.
> >
> >        Nets crossing region boundaries must be part of a slice macro
> >
> It appears that you did not route your PRM's external signals through
> bus macros. Every signal (except for global clocks) that's between
> your recofigurable modules and the static part of your design has to
> be routed through a bus macro. I think there's a section on that at
> the beginning of the EAPR user guide.
>
> Best,
> Enno
> --
> Dipl.-Ing. Enno Lübbers
> Fachgebiet Technische Informatik
> Universität Paderborn
>
> Warburger Str. 100
> 33098 Paderborn
>
> http://wwwcs.upb.de/cs/ag-platzner
> Telefon: 05251 / 60-5397
> Telefax: 05251 / 60-5377
>
>
>
>