Re: [partial-reconfig] About PAR errors of EAPR
Hi Enno,
I changed PRM's area, and placed bus macros between PRM and IOBs. Then it's OK.
Thank you very much!
Best regards,
JinXi
2007/10/10, Enno Luebbers <enno.luebbers@xxxxxxxxxxxxxxxx>:
Hi Jin Xi,
> But the signals that's between PRM and IO do not cross through the
> static part. Thus, is BM necessary?
All the IOBs are considered part of the static logic - they are
instantiated at the top level. I guess if your reconfigurable area
included the used IOBs at its edge, bus macros would be unnecessary,
but I have never tried that.
Best regards,
Enno
--