[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: [partial-reconfig] PlanAhead error in Microblaze-based partially reconfigurablesystem
- To: <partial-reconfig@xxxxxxxxxxxxxx>
- Subject: RE: [partial-reconfig] PlanAhead error in Microblaze-based partially reconfigurablesystem
- From: "Mati Nahshon" <mati.nahshon@xxxxxxxxx>
- Date: Sun, 9 Mar 2008 01:42:34 +0200
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=gamma; h=domainkey-signature:received:received:from:to:references:subject:date:message-id:mime-version:content-type:content-transfer-encoding:x-mailer:x-mimeole:in-reply-to:thread-index; bh=uSim3Q3k6zB3frs1iZ5ZaptcnLpuKxEWOOIXG4zYoOw=; b=tYxciHi68c6/L8NzI0QZFJNl4hasllYy0RsSKUmVDV2pdDdaQ1x1hO8naB1CuX9Zk8co/1LOsYAjn5DQ0XSOC1ViQV7ux55fdza6x9D6kisHJZx2YN1ao2nEUPMLIAJPRCucvXf732r6XIs64zMtPeBx37eZQFXld8zrXVykrDE=
- Domainkey-signature: a=rsa-sha1; c=nofws; d=gmail.com; s=gamma; h=from:to:references:subject:date:message-id:mime-version:content-type:content-transfer-encoding:x-mailer:x-mimeole:in-reply-to:thread-index; b=Bo6I/pYfoQ8bnKQ03atjHsxFyaEM3HKdTNTVEDzDrxN2vcvO4CmGK4NR9sS2fx7fIcyiKsoNgmc+BDl85Wpa03TuR3skAyAgtdQ87XXdbHXkBRIK+HRxKXnx2ciBohdrI0QF45d/CZVVNgKX+uqU4rNXW83J/iLAAUv0NxjKijA=
- In-reply-to: <20080306152527.1su8wo08g4o04kgw@xxxxxxxxxxxxxxxxxxxxx>
- References: <20080306152527.1su8wo08g4o04kgw@xxxxxxxxxxxxxxxxxxxxx>
- Reply-to: partial-reconfig@xxxxxxxxxxxxxx
- Sender: owner-partial-reconfig@xxxxxxxxxxxxxx
- Thread-index: Ach/5qzlkoMIqgIRToGJCNP+LTPlogBjyMkQ
If I am not mistaken your bus macros are not placed on the top level, am I
correct?
If so, move them to the top outside all the area groups.
Mati
-----Original Message-----
From: owner-partial-reconfig@xxxxxxxxxxxxxx
[mailto:owner-partial-reconfig@xxxxxxxxxxxxxx] On Behalf Of
adarshs@xxxxxxxxxxxxxxxxx
Sent: Friday, March 07, 2008 12:25 AM
To: partial-reconfig@xxxxxxxxxxxxxx
Subject: [partial-reconfig] PlanAhead error in Microblaze-based partially
reconfigurablesystem
Hello Everyone,
I am developing a system where Microblaze helps to partially reconfigure
certain
modules on Virtex-5. I have developed the reconfigurable modules as OPB
slaves.
When I define the static and PR regions in PlanAhead, and try implementing
the
static portion, I get the following error:
ERROR:Map:95 - Every module in the design should have an AREA_GROUP
property.
There is no AREA_GROUP property on module root block
opb_socket_bridge_0/opb_socket_bridge_0/Control1_BM
It tells me that no AREA_GROUP constraints are provided for the bus macros.
But
Xilinx white papers say that bus macros must not have AREA_GROUP
constraints.
I would appreciate it if anyone could tell me how to solve this problem.
Thank you,
Adarsha
___________________________
partial-reconfig mailing list
partial-reconfig@xxxxxxxxxxxxxx
Mailing List Archive : http://www.itee.uq.edu.au/~listarch/partial-reconfig/
___________________________
partial-reconfig mailing list
partial-reconfig@xxxxxxxxxxxxxx
Mailing List Archive : http://www.itee.uq.edu.au/~listarch/partial-reconfig/